The Huawei AC650-256AP Dubai is an advanced wireless access controller (AC) engineered by Huawei to address the specific demands of small and medium-sized enterprise (SME) network environments. Designed with cutting-edge technology, this device works in perfect harmony with Huawei access points (APs) to create highly dependable wireless networks. It is ideally suited for various settings, including small campus networks, the office networks of smaller enterprises, and locations where hotspot coverage is essential.
With the capability to manage up to 256 access points, the Huawei AC650-256AP Dubai ensures robust and consistent network performance. This device also offers substantial support for up to 2048 simultaneous stations (STAs), making it an excellent choice for providing extensive coverage and reliable connectivity across numerous devices. Whether for a small business or a medium-sized enterprise, the Huawei AC650-256AP Dubai delivers the powerful networking solutions needed to maintain seamless, high-quality connections in demanding environments.
Technical Specifications
Description | AC650-256AP mainframe (10*GE ports, 2*10GE SFP+ ports, with the AC/DC adapter) |
Part Number | 02355NCH |
Model | AC650-256AP |
First supported version | V200R022C10 |
Installation Type |
|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic: 43.6 mm x 250 mm x 210 mm (1.72 in. x 9.84 in. x 8.27 in.)
Maximum: 43.6 mm x 250 mm x 215 mm (1.72 in. x 9.84 in. x 8.46 in.) |
Weight without packaging [kg(lb)] | 1.9kg |
Storage | Nand FLASH 1GB |
Console port | RJ45 |
Maximum power consumption [W] | 23.58 W |
Maximum heat dissipation [BTU/hour] | 80.45 BTU/hour |
Power supply mode | DC adapter |
Service port surge protection | 6 kV in common mode |
Types of fans | None |
Maximum number of physical ports on the entire device | 2 x 10GE (SFP+) + 10 x GE (RJ45) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) (If the altitude is in the range of 1800 m to 5000 m, the temperature decreases by 1°C or 1.8°F every time the altitude increases by 300 m.) |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | –60 m to +5000 m (–196.85 ft to +16404.20 ft) |
Atmospheric pressure [kPa] | 53kPa – 106kPa ETSI 300 019-2-3 |
Ground | Ground |
USB | 1 x USB 2.0 (host type A) port |
MTBF [year] | 50 year |
MTTR [hour] | 2 hour |